Second Wind 9000 Instruction Manual Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 9
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
7
1 Make sure that the unit is plugged into
an outlet that is always on.
2 Check the on/off switch to make sure it
is on.
3 If the lamp is still not on, switch the
unit off, unplug the power cord and
check the fuse.
4 Make sure the lamp is not broken and
that it is in the socket.
5 Check to see if pin on door is activating
the interlock switch
6 If the lamp is still not on check the
ballast.
7 Check the input power by testing the
outlet for 120 VAC.
8 Test the resistance of the ballast.
Unplug the power cord. Measure the
resistance from the black lead on the
input side of the ballast to the blue lead
on the output side of the ballast. To
contact the blue lead you may need to
remove the lamp and put the multi-
meter probe into the corresponding
socket opening. The resistance should
be 7-12 ohms. If the resistance is less
than 7 ohms, replace the ballast.
9 If everything else has been checked and
is fine, but the lamp is still out, the
ballast starter is blown and the ballast
should be replaced.
Replacement Parts
1 Ballast 120 vac #1060E
2 Interlock Switch #1047
3 On/Off Switch 120 V #1061
4 Fuse Assembly #1054
5 Fuse #1055
6 Power Cord
7 Lamp Connector #1014
8 18“ Lamp(Model 9000) #1076R
9 14” Lamp(Model 9016) #1082R
10 Filter 20 x 25 #9001R
Filter 16 x 25 #9016R
Periodic Maintenance
1. Turn off power, remove front door and filter.
Inspect filter. Semi-annual to Annual filter replacement recommended.
2. Use cotton ball and alcohol to clean glass lamp.
Inspect lamp (Recommended replacement of lamp—every 12 months.).
3. Reinstall filter and front door panel. Turn unit on.
The Second Wind Air Purifier has been tested effective in the destruction and reduction of bacteria, viruses and
fungus under various conditions. The effectiveness of this device may vary depending upon room area and rate
of circulation. The health aspects associated with this product were not investigated by U.L.