5
Second Wind Air Purifier lamps are designed to be on all the time. After approximately 9000-11000 hours of
operation the lamps intensity will decrease. Installation of a replacement lamp is best handled by a HVAC
Contractor.
1 Turn unit off and unplug the power cord.
After lamp has cooled proceed.
2 Use duct board installation template to mark
mounting location (Fig.1)
3 Cut out mounting hole on the outside of the
marked line.
4 Mount black block assembly and secure to the
duct using #10, 1 1/4 inch, self tapping screws.
(Fig.2)
5 Insert lamp into mounting block, secure in
place using the RU lamp holder and the #8, 3/4
inch flat head wood screws provided. (Fig.3 &
Fig.4)
6 Connect the lamp by lining up the lamp pins
to the connector. Secure the lamp connector to the
block using two #8 , 3/4 inch, round head metal
screws provided. (Fig.5)
7 Secure cords and mastic/tape any holes in the
ductwork.
8 Plug unit in and turn on.
Installed
If the lamps are dirty or have
fingerprints on them, use alcohol to
remove.